Product model | product name | Voltage level | Executive standard |
YJV YJLV ZR-YJV ZR-YJLV | XLPE insulated PVC sheathed power cable XLPE insulated PVC sheathed flame retardant power cable | 0.6/1~26/35 | 1、GB/T12706-2002 (IEC60502) |
YJY YJLY ZR-YJY ZR-YJLY | XLPE insulated PE sheathed power cable XLPE insulated PE sheathed flame retardant power cable | ||
YJV22 YJLV22 ZR-YJV22 ZR-YJLV22 | XLPE insulated steel tape armored PVC sheathed power cable XLPE insulated steel tape armored PVC sheathed flame retardant power cable | ||
YJV23 YJLV23 ZR-YJV23 ZR-YJLV23 | XLPE insulated steel tape armored PE sheathed power cable XLPE insulated polysteel tape armored vinyl sheathed flame retardant power cable | ||
YJV32 YJLV32 ZR-YJV32 ZR-YJLV32 | XLPE insulated fine steel wire armored PVC sheathed power cable XLPE insulated fine steel wire armored PVC sheathed flame retardant power cable | ||
YJV33 YJLV33 ZR-YJV33 ZR-YJLV33 | XLPE insulated fine steel wire armored PE sheathed power cable XLPE insulated fine steel wire armored PE sheathed flame retardant power cable | ||
YJV42 YJLV42 ZR-YJV42 ZR-YJLV42 | XLPE insulated thick steel wire armored PE sheathed power cable XLPE insulated thick steel wire armored PE sheathed flame retardant power cable | ||
YJV43 YJLV43 ZR-YJV43 ZR-YJLV43 | XLPE insulated thick steel wire armored PE sheathed power cable XLPE insulated thick steel wire armored PE sheathed flame retardant power cable |
Product number | Scope of application | Instructions for use |
YJV YJLV ZR-YJV ZR-YJLV YJY YJLY ZR-YJY ZR-YJY | Suitable for indoor outdoor laying. It can withstand certain laying traction, but cannot withstand mechanical external force. Single-core cables are allowed to be laid in magnetic conduits. | 1. Working temperature: 1-35KV cable core allows long-term high working humidity of 90 ℃. 2. The short-circuit temperature of the line cannot exceed 250, the duration is less than 5 seconds. 3. When the laying temperature is lower than 0℃, it must be preheated. 4. Laying drop: The laying is limited by the horizontal drop. 5. Bending radius of single core: 20(d+D)±5%, multi-core: 15(d+D)±5% D=actual outer diameter of cable sample (mm) d=actual diameter of conductor |
YJV22 YJLV22 ZR-YJV22 ZR-YJLV22 YJV23 YJLV23 ZR-YJV23 ZR-YJLV23 | Suitable for buried laying, can withstand mechanical external force, but can withstand excessive tensile force | |
YJV32 YJLV32 ZR-YJV32 ZR-YJLV32 YJV33 YJLV33 ZR-YJV33 ZR-YJLV33 | It is suitable for water high drop areas, can withstand considerable pulling force mechanical external force. | |
YJV42 YJLV42 ZR-YJV42 ZRYJLV42 YJV43 YJLV43 ZR-YJV43 ZR-YJLV43 | Suitable for water high drop areas, can withstand mechanical external force considerable tensile force |